Skip to content
  • Proudly Made in the USA
  • QUOTE
  • 888.653.3333
  • sale@moishaglass.com
  • Products
    • Fire Protective Glass Tested to NFPA 252/257, UL 9/10C, ULC S104/S106; Blocks smoke and flames.
    • SuperLite® I
    • SuperClear® 45-HS
    • SuperClear® 45-HS-LI
    • SuperLite® I-XL
    • SuperLite® I-XL IGU
    • SuperLite® X-45/60/90
    • SuperLite® II-XL 45
    • Ceramics
    • Fire Resistive Glass Tested to ASTM E119 / UL 263 / ULC S101; Blocks smoke, flames and radiant heat.
    • SuperLite® II-XL 60
    • SuperLite® II-XL 90
    • SuperLite® II-XL 120
    • SuperLite® II-XLB 60
    • SuperLite® II-XLB 120
    • SuperLite® II-XLM 60
    • SuperLite® II-XLM 120
    • SuperSecure® II-XLS 45-120
    • Fire Rated Walls 60-120 minute fire resistive glass and frame assemblies tested to ASTM E119 / UL 263 / ULC S101.
    • GPX® Architectural Series Fire Resistive
    • GPX® Curtain Wall
    • GPX® Hurricane
    • GPX® Ballistic
    • GPX® Blast System
    • GPX® EZ Frame
    • Fire Rated Doors Full vision 20-45 minute fire protective doors and 60-90 minute temperature rise doors tested to NFPA 252 / UL 10C / ULC S104.
    • GPX® Architectural Series Fire Protective
    • GPX® Architectural Series Fire Resistive
    • GPX® Builders Series Fire Protective
    • GPX® Builders Series Temperature Rise
    • GPX® Hurricane
    • GPX® Ballistic
    • GPX® Vision Kit
    • Fire Rated Openings 20-45 minute fire protective glass and framing assemblies tested to NFPA 257 / UL 9 / ULC S106.
    • GPX® Architectural Series Fire Protective
    • GPX® Builders Series Fire Protective
    • GPX® EZ Frame
    • Fire Rated Floors 60-120 minute fire resistive glass floor assemblies tested to ASTM E119 / UL 263 / ULC S101.
    • GPX® FireFloor
    • Fire Rated Fences 20-60 minute fire rated glass fence for WUI areas or designated fire zones.
    • SAFTI FENCE
    • Specialty Glass
    • Laminated Safety Glass
  • Literature
  • Specs
  • Details
  • Videos
  • Resources
    About Us
    Videos
    Case Studies
    Articles
    Blogs
    Continuing Education
    Literature
    BIM Library
    Industry Links
    Press Releases
    Testimonials
    Technical Bulletins
    Newsletters
    Product Selector
  • Blog
  • Contact
    Contact Us
    Meet Our Team
    Find Your Local Rep
    Request a Quote
  • Products
    • Fire Protective Glass
    • Fire Resistive Glass
    • Fire Rated Walls
    • Fire Rated Doors
    • Fire Rated Openings
    • Fire Rated Floors
    • Fire Rated Fences
  • Literature
  • Specs
  • Details
  • Videos
  • Resources
    • About Us
    • Product Selector
    • Articles
    • Blogs
    • BIM Library
    • Case Studies
    • Newsletters
    • Press Releases
    • Continuing Education
    • Literature
    • Technical Bulletins
    • Testimonials
    • Industry Links
    • Videos
  • Gallery
  • Contact
    • Contact Us
    • Meet Our Team
    • Find Your Local Rep
    • Request a Quote
Menu
  • Products
    • Fire Protective Glass
    • Fire Resistive Glass
    • Fire Rated Walls
    • Fire Rated Doors
    • Fire Rated Openings
    • Fire Rated Floors
    • Fire Rated Fences
  • Literature
  • Specs
  • Details
  • Videos
  • Resources
    • About Us
    • Product Selector
    • Articles
    • Blogs
    • BIM Library
    • Case Studies
    • Newsletters
    • Press Releases
    • Continuing Education
    • Literature
    • Technical Bulletins
    • Testimonials
    • Industry Links
    • Videos
  • Gallery
  • Contact
    • Contact Us
    • Meet Our Team
    • Find Your Local Rep
    • Request a Quote
Articles
Code Education
2012 IBC Changes Designed to Make Fire-Rated Glazing Specification Easier
Code Education

2012 IBC Changes Designed to Make Fire-Rated Glazing Specification Easier

ByDiana S
| September 20, 2014

2012 IBC Changes Designed to Make Fire-Rated Glazing Specification Easier

2012 IBC Changes Designed to Make Fire-Rated Glazing Specification Easier. While the requirements are not new, the new marks for fire rated glass are. They make specification more straightforward. This article appeared in US Glass Magazine in October 2011.

For the first time, the 2012 International Building Code (IBC) has provided a guide advising where to use fire-protective versus fire-resistive glazing in door, window and wall assemblies. The revised Chapter 7 tables now clearly address size limits and appropriate fire-rated glazing (FRG) applications in interior and exterior walls, and exit enclosures and passageways. The new tables help professionals specify where to use fire-protective versus fire-resistive glazing in FRG assemblies, and avoid the misuse of FRG products for end-uses prohibited by the IBC.

These provisions are not new, says Diana San Diego, director of marketing at SAFTI FIRST in San Francisco. Rather, “These are … a clarification of the 2006 and 2009 editions of the IBC,” she explains. “Even though the new tables will not be adopted locally until jurisdictions accept the 2012 IBC, they are useful today in understanding the 2006 and 2009 IBC glazing requirements.”

The requirements contained in the new tables have been in effect since the 2006 IBC, and conform to what NFPA 80 provided in the 1999 and 2007 NFPA 80 editions, which are incorporated by reference in the 2012 IBC.

“This will benefit architects immensely as they select the correct fire-rated glass product for their application,” San Diego says. “This helps glaziers, too, because they can have a better understanding of the types of fire-rated glass products that they are installing.”

Devin Bowman, national sales manager at Technical Glass Products in Snoqualmie, Wash., agrees. “For fire-rated glass manufacturers and suppliers, the updated tables help clarify use of materials,” he says. “Depending on how they promoted their products, this could require changes in product literature to be consistent with the latest codes. Manufacturers and suppliers will also need to use the new marking system, but that is a relatively straightforward change.”

Architects, specifiers and glaziers need to be aware of the new fire-rated glass code clarifications as their local jurisdictions adopt them, Bowman says. “As with past codes, there’s often a lag as cities, counties and states switch from their current codes to the latest version, but it’s necessary to know what’s coming.”

He adds, “It’s crucial to pay attention to glass size limits, and to understand where ‘fire-protection’ and ‘fire-resistance’ rated products are allowed. Fire protection glazing defends against the spread of flames and smoke, while fire resistance glazing also blocks heat transfer. This is a critical distinction as the higher level of protection is necessary in certain instances such as exit passageways and for fire walls and fire barriers.”

The same marking system for fire resistance- and fire protection-rated glazing also was included in the 2012 edition of National Fire Protection Association 101, the Life Safety Code, says Thomas S. Zaremba, an industry consultant and partner for Roetzel & Andress in Toledo, Ohio.

There is significant value to having this marking system in place in the codes, Zaremba says. “First, from the perspective of fire-rated glazing manufacturers, the users of fire-rated glazing and the building code officials, it enables all of them to identify directly from the label found on the glazing in the field exactly what fire tests the glass has been subjected to. Second … through the new marking system, the table now shows exactly how fire-rated glazing must be marked in virtually every applications where fire-rated glazing is required.”

Given the increased level of certainty that these provisions provide in assuring that the right fire-rated glazing is being used in the right application, “it should be easier for fire-rated glazing manufacturers to provide the specific applications for their inventories of different types of fire-rated glazings; easier for specifiers to incorporate fire-rated glazing into their construction plans and drawings; easier for installers to identify from the label the right glass for the right applications in the field; and easier for building code officials to determine that the right glass has in fact been installed in the right applications,” Zaremba says.

The new code also simplifies the fire-rated glazing label scheme by reducing the number of markings describing where the glass can be used and which tests it has passed, Bowman says. Marks now include ‘W’ for fire-resistance-rated glazing meeting wall assembly criteria; ‘OH’ for glass meeting fire window assembly criteria, including the hose stream test; ‘D’ for glass meeting fire door assembly criteria; ‘H’ for glass meeting the fire door assembly hose stream test; and ‘T’ for glazing meting temperature rise criteria. As before, a two- or three-digit number shows the fire rating in minutes.

Another important change in the 2012 IBC is clarification in Section 703.4 that automatic sprinklers are not allowed during fire-rated materials testing. Fire ratings for glass and other building materials must be earned based on their own performance, and not as protected by supplemental systems. “This provides an additional margin of safety for building occupants in the event sprinklers fail during a real-world fire,” Bowman says.

At its next meeting, the ICC’s Code Technology Committee is planning to review the changes made to the fire-rated glazing provisions in the 2012 IBC meeting to determine whether any additional changes may be required. “Perhaps using a single table for both fire-rated windows and fire-rated doors in the IBC will be considered for the 2015 edition of the IBC,” Zaremba says.

NFPA 257 Close to Finishing 2012 Updates

The National Fire Protection Association (NFPA) Technical Committee is close to releasing a 2012 edition of NFPA 257, Standard on Fire Test for Window and Glass Block Assemblies. There are really only two substantive changes, says Thomas S. Zaremba, partner at Roetzel & Andress in Toledo, Ohio. The first modifies section 4.1.2, which dealt with furnace temperature at the start of the test.The 2007 edition of the standard required the temperature inside the furnace at the beginning of the test to be ambient. That has been changed because the temperature of a cold furnace at the start of a fire test is not significant, Zaremba explains.

“What is significant is the temperature of the test laboratory where the specimens are located before the test,” he says. Accordingly, this section will now read: “At the start of the fire test, the ambient laboratory air temperature shall be in the range between 50-90 degrees F.”

The second substantive change will delete section 4.3.4 from the 2012 edition. That section addresses “neutral pressure” testing, and since all codes now require testing under positive pressure, this section is no longer necessary.
www.nfpa.org/257

New ASTM Standard for Glass and Glazing Systems Published

ASTM F2912-11, Standard Specification for Glazing and Glazing Systems Subject to Airblast Loadings, was published August 11. The specification covers exterior windows, glazed curtainwalls, glazing panels in doors and other glazed protective systems used in buildings that may be subjected to intentional or accidental explosions.

“ASTM F 2912 was created to provide guidance to those interested in incorporating bomb-blast resistance into their facilities when they don’t have the benefit of a government specified mandate for performance,” says Julia Schimmelpenningh, global applications manager of advanced interlayers, a division of Solutia Inc. in Springfield, Mass. “It is structured to ensure the critical parameters for blast design are communicated in the specification: load, duration, protection/hazard level, this ensures a more rapid translation of product configurations for quotes and delivery. The publication of this specification is hoped to demystify blast resistance to some extent and make it a much more common consideration for commercial and industrial facilities.”

The specification addresses only glazing and glazing systems, and does not address the structural integrity and functionality of door assemblies. It assumes that the designer has verified that other structural elements have been adequately designed to resist the anticipated air-blast pressures.

The specification was designed for all glazing, glazing systems and glazing retrofit systems. It does not determine the assessment of a facility nor acceptable hazard ratings. Threat and risk assessment shall have already been performed and the acceptable hazard rating defined.

The specification will be under a 5-year review cycle.
www.astm.org

Share:
PrevNext ArticleUpdate: New Marks for Fire Rated Glazing Assemblies in 2022
Previous Article2012 IBC Updates Fire Rated Glass TablesNext
Back to Articles

Engineering. Design. Code.

Whether you’re looking for fire-rated walls, doors, openings, floors or a specialty service, we have the solution for you. With over 40 years of experience in testing, innovating, and providing technologically advanced fire-rated glass and framing products, we deliver unyielding performance and quality at a competitive price.

Let's Talk!

  • 888.653.3333
    (English)
  • 888.653.3333 ext. 652
    (Spanish)
  • sale@moishaglass.com
  • Representative Map
Contact
Phone
888.653.3333 - English
888.653.3333 ext. 652 - Spanish
Fax
888.653.4444
Email
sale@moishaglass.com
Address
Corporate
100 N Hill Dr, Ste12, Brisbane, CA 94005
Factory
220 S R Street, Merced, CA 95341

Sign up for our Newsletter!

Get notified of industry updates and new product alerts.

AFFILIATE COMPANIES
Division 5
1850 Grogan Ave, Merced, CA 95341
888.653.3333
Division 8
1891 Wardrobe Ave, Merced, CA 95341
866.848.2667
© 2025 SAFTI FIRST. All rights reserved.​
Disclaimer & Privacy Policy | Cookie Policy
Instagram Linkedin Facebook Youtube Vimeo
Suggested Pages
Case Studies
Request a Quote
SuperClear® 45-HS-LI
Continuing Education
Request a Quote
Continuing Education
Videos
SuperClear® 45-HS-LI
Case Studies
This website uses cookies to ensure you get the best experience on our website.

This website uses cookies to ensure you get the best experience on our website.


This website uses cookies to improve user experience. A cookie file is stored in your web browser and allows the website to recognize you and make your next visit easier and the website more useful to you. By using our website, you consent to all cookies in accordance with our Cookies Policy. Learn more.
Functional Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
Manage options Manage services Manage vendors Read more about these purposes
View preferences
{title} {title} {title}